Tristate Machinery Dismantlers Forum > STATE OF IOWA
> Machine Parts
> New
> New fluke 787 processmeter - ** ** - - msrp 699 usd
New fluke 787 processmeter - ** ** - - msrp 699 usd
Unit is *NEW* with test leads, alligator clips, CD, and manual
If needed we can Calibrate for an additional $39.99 a $89.99 service
A maintenance and calibration tool that will be at home in every instrumentation technician's tool box, the Fluke 787 ProcessMeterT combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution. The 787 offers:
* Simultaneous mA and % of scale readout on mA output.
* Min/Max/Average/Hold/Relative modes.
The Fluke 787 ProcessMeterT puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you're tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.
Here's the power the 787 ProcessMeterT puts into your hands.
* Precision 1000V, 440 mA digital multimeter
* Measure ac and dc volts, ac and dc current, resistance, continuity, and frequency
* 0.1% dc voltage accuracy
* 0.05% dc current accuracy, 1 A resolution to 30 mA
* Simultaneous mA and % of scale readout
* True rms ac voltage measurement to 1 kHz
* Frequency measurement to 20 kHz
* Min/Max/Average/TouchHold/Relative modes
* Diode test and continuity beeper
* DC current source/loop calibrator
* 20 mA current source/simulator
* Manual step (25%, coarse, fine) plus auto step and auto ramp
* Externally accessible battery for easy battery changes
* 1000V overload protection on V, ohms, frequency
* 150V overload protection on mA, backed-up by 440 mA 1000V fuse
* Designed to meet 1000 volt IEC 1010 Cat III standards
DC Current Output (Internal battery operation)
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to 24.000 mA
12 V compliance, or 500 ohms @20 mA
DC Current Simulate (External 24 volt loop supply)
Automatic: Slow Ramp, Fast Ramp, 25% step
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):
Best Accuracy (% of reading + LSD:
400.0 Ohms, 4.000 kOhms, 40.00 kOhms, 400.0 kOhms, 4.000 MOhms, 40.00MOhms
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz
2.400 V (measures diode voltage drop)
Beeps for resistance < approx. 100 ohms
Maximum voltage applied between any jack and Earth Ground
95% up to 30 C; 75% up to 40 C; 45% up to 50 C; 35% up to 55 C
Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III
32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x 7.35 in L)
Size, with holster and Flex-Stand
52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86 in W x 7.93 in L)
369 g (13 oz); with holster and Flex-Stand 638 g (22.5 oz)